power usage effectiveness (PUE)



Word of the Day
Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google


DEFINITION - Power usage effectiveness (PUE) is a metric used to determine the energy efficiency of a data center. PUE is determined by dividing the amount of power entering a data center by the power used to run the computer infrastructure within it. PUE is therefore expressed as a ratio, with overall efficiency improving as the quotient decreases toward 1. PUE was created by members of the Green Grid, an industry group focused on data center energy efficiency. Data center infrastructure efficiency (DCIE) is the reciprocal of PUE and is expressed as a percentage that improves as it approaches 100%.



How to Determine PUE

1. Take a measurement of energy use at or near the facility's utility meter. If the data center is in a mixed-use facility or office building, take a measurement only at the meter that is powering the data center. If it is not on a separate utility meter, estimate the amount of power being consumed by the non-data center portion of the building and remove it from the equation.

2. Measure the IT equipment load after power conversion, switching, and conditioning is completed. According to The Green Grid, the most useful measurement point is at the output of the computer room power distribution units (PDUs). This measurement should represent the total power delivered to the server racks in the data center.

According to the Uptime Institute, the typical data center has an average PUE of 2.5. This means that for every 2.5 watts in at the utility meter, only one watt is delivered out to the IT load. Uptime estimates most facilities could achieve 1.6 PUE using the most efficient equipment and best practices.

CONTRIBUTORS: Mark Fontecchio
LAST UPDATED: 07 May 2008

Read more about power usage effectiveness (PUE):
- The Green Grid offers a downloadable white paper that explains PUE and DCIE further. (PDF)


Do you have something to add to this definition? Let us know.
Send your comments to techterms@whatis.com


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us    Add to Google


RELATED CONTENT
EU launches Code of Conduct for Data Centers
The European Union has announced a strict new code for data center energy conservation in order to fight global warming. This places the EU further...
HP announces Dynamic Power Capping for ProLiant servers
The new Dynamic Power Capping feature enables data center managers to set a power threshold based on how much power a server uses.
Data center cooling: Air-side and water-side economizers
Air-side and water-side economizers can provide cost savings for data centers feeling the heat from rising energy bills.




Data Center Decisions: Lights-Out or Managed Data Center?
HomeNewsTopicsITKnowledge ExchangeTipsBlogsMultimediaWhite PapersEvents
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides enterprise IT professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective IT purchase decisions and managing their organizations' IT projects - with its network of technology-specific Web sites, events and magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2005 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts